Our Research & Evaluation Methodology

How we aggregate manufacturer technical specifications, apply transparent mathematical formulas, and present comparative buying guides for portable power stations.

Important Clarification: We do not test products ourselves. We are not an engineering testing laboratory. All comparisons, sizing estimates, and specification tables published on this site are compiled strictly from published manufacturer technical datasheets, user manuals, and certified safety listings.

What We Do vs. What We Do Not Do

Swipe to view table →
Our editorial practices comparison table
What We Do What We Do Not Do
Compile numbers directly from official manufacturer datasheets and user manuals. Never claim lab testing when we have not tested products ourselves.
Record the date checked and cite the exact source for every metric. Never publish subjective star ratings or proprietary benchmark scores.
Clearly label unverified metrics as Not checked until confirmed. Never guess or interpolate missing technical specifications.
Disclose mathematical formulas and efficiency loss assumptions (85% inverter baseline). Never use marketing buzzwords or unfounded manufacturer claims.
Place clear affiliate disclosures directly adjacent to commercial links. Never alter technical specifications based on commission rates.

Where Our Data Comes From

Every technical figure on SizeMyWatts — including battery capacity (Wh), continuous inverter wattage (W), surge capacity, weight, dimensions, and solar input limits — originates from public manufacturer documentation. When manufacturer datasheets omit a figure (such as noise levels in decibels or standby idle power consumption), we report it as unstated rather than guessing.

Mathematical Calculations & Assumptions

Our runtime estimations and sizing calculator rely on standard electrical engineering principles:

How the SizeMyWatts Score works

The SizeMyWatts Score is a 100-point, spec-based evaluation designed to provide an objective, transparent benchmark across portable power stations. Scores are computed from manufacturer specifications; we do not run hands-on tests. Price is not part of the score because prices change daily.

Scores are not published yet while we complete spec data for every model.

Core Scoring Principles

The 9 Scoring Criteria (100 Points Total)

Swipe to view criteria →
SizeMyWatts Score 100-point evaluation criteria and formulas
Criterion Max Points Mathematical Formula / Absolute Scale Evaluation Rule
Battery Capacity 15 pts 15 × log10(Wh / 200) (200 Wh = 0 pts, 2,000 Wh = 15 pts) Clamped at 15.0 max. Measures total stored usable energy.
Continuous AC Output 10 pts 10 × log(W / 300) / log(8) (300 W = 0 pts, 2,400 W = 10 pts) Clamped at 10.0 max. Evaluates sustained pure sine wave inverter wattage.
Surge Output 5 pts 5 × log(Surge W / 300) / log(8) (same scale × 0.5) If brand does not state surge, continuous AC is used with note "surge not stated — continuous used".
Max Solar Input 15 pts 15 × (W - 100) / 900 (100 W = 0 pts, 1,000 W = 15 pts) Clamped at 15.0 max. Measures off-grid replenishment throughput. 0 pts if not stated.
Portability (Wh/lb) 15 pts 15 × (Wh/lb - 25) / 25 (25 Wh/lb = 0 pts, 50 Wh/lb = 15 pts) Clamped at 15.0 max. Rewards gravimetric energy density.
AC Charge Speed 10 pts 10 × (300 - T) / 270 (30 min = 10 pts, 300 min = 0 pts, linear) Strictly evaluated on manufacturer 0–80% AC charge time (never derived from 0–100%). 0 pts if not stated.
Cycle Life 10 pts 10 × (Cycles - 2,000) / 4,000 (2,000 cycles = 0 pts, 6,000 cycles = 10 pts) Clamped at 10.0 max. Evaluates cell longevity to manufacturer retention threshold. 0 pts if not stated.
Standard Warranty 10 pts 2 points per year of standard manufacturer warranty (max 10 pts / 5 yrs) Excludes optional extensions requiring registration or marketing actions. 0 pts if not stated.
Verified Features 10 pts UPS/EPS fast transfer (4 pts), smart app control (3 pts), battery expandable (3 pts) Points awarded only when explicitly stated and verified in manufacturer documentation.

Score Presentation & Rating Bands

The total point sum (out of 100) is normalized to a 10-point scale rounded to 1 decimal place (e.g. 7.4 / 10), accompanied by a four-tier classification band:

Use of AI Assistance

This site utilizes artificial intelligence tools for research aggregation, text drafting assistance, and code generation. Every page undergoes human editorial review before publication. Artificial intelligence is not a source of facts; every technical figure must trace directly to a cited manufacturer datasheet.

Errors & Corrections Policy

Manufacturer specifications and firmware capabilities evolve. If you identify a discrepancy or an outdated figure in our catalog, please contact our research desk at contact@sizemywatts.com with the model name, datasheet URL, and section number. We verify and update records promptly.